79% efficient solar panel stays 28°F cooler under intense sunlight with microchannel pipe

Wait 5 sec.

​Researchers from the University of Nottingham in the UK and Shandong Jianzhu University in China have developed a hybrid solar panel that uses a microchannel heat pipe (MCHP) to cool photovoltaic cells while recovering waste heat to produce hot water, achieving an overall energy efficiency of nearly 79 percent.​The team combined a conventional solar panel with a flat microchannel heat pipe and water-cooling system, allowing excess heat that would normally reduce electrical performance to be transferred into circulating water instead.To optimize the system, the researchers also created a quasi-two-dimensional mathematical model that predicts how changes in the heat pipe design and water flow affect electrical output, thermal performance, and pumping power consumption.​”The optimal MCHP length ratio and cooling water flow rate are identified to provide practical design guidelines for balancing thermal efficiency against pumping power consumption,” the researchers said.​Cooling panel while harvesting heat​Conventional photovoltaic panels lose efficiency as their temperature rises, particularly during periods of intense sunlight. While much of the incoming solar energy is converted into heat, only a fraction becomes electricity.​The researchers sought to recover that wasted thermal energy while simultaneously lowering the panel’s operating temperature.​To test the concept, they bonded a commercial 210-watt polycrystalline silicon solar panel to the evaporator section of a flat microchannel heat pipe using thermally conductive silicone.​The heat pipe contained parallel microchannels and used R141b as the working refrigerant. A dual-passage water manifold attached to the condenser section carried away heat and transferred it to a water storage tank.​The prototype was then placed alongside a conventional solar panel under an indoor solar simulator, with irradiance ranging from 200 to 940 watts per square meter.​Throughout the tests, ambient temperature remained at 98.6°F , while cooling water entered the system at 95.9°F  and circulated at 0.138 cubic meters per hour.​Lower temperatures, higher efficiencyUnder peak solar irradiance of 940 W/m², the hybrid system kept the photovoltaic cells at 154°F, compared with 182°F  for the conventional panel.​That lower operating temperature increased electrical efficiency from 10.18 percent for the standard panel to 11.15 percent for the heat-pipe-cooled design.​Across the full testing range, the photovoltaic-thermal module achieved average electrical, thermal, and weighted overall efficiencies of 11.87 percent, 47.10 percent, and 73.71 percent, respectively.​Further modeling showed performance could be improved even more.​The researchers found that electrical efficiency increased as cooling water flow rose, reaching an optimum at approximately 0.2 cubic meters per hour. Beyond that point, additional pumping energy outweighed further gains, while thermal efficiency improved only marginally.​Similarly, increasing the proportion of the panel covered by the microchannel heat pipe enhanced cooling performance, although benefits diminished once the heat-pipe length ratio exceeded 0.22.​Combining a 0.22 heat-pipe length ratio with a 0.2 m³/h water flow produced the best balance between electrical output, thermal recovery, and pumping power, resulting in a weighted overall efficiency of 78.94 percent.​The researchers said the findings demonstrate the potential of integrating advanced heat-pipe cooling with photovoltaic systems to improve energy utilization, particularly in regions experiencing high solar irradiance, while simultaneously producing usable thermal energy for domestic or industrial applications.​The findings were published in Applied Thermal Engineering.