China’s EVE Energy unveiled a 5 MWh battery storage system for AI data centers at the RE+ 2026 energy exhibition in Las Vegas. The system fits inside a standard 20-foot container and is part of a lineup built to manage electricity supply from the grid to individual server racks.The Chinese battery maker also introduced a 660 kW backup cabinet and a rack-level system that can switch to backup power in less than two milliseconds, according to the company. The products address different demands at AI facilities, where electricity use can fluctuate in fractions of a second even as operators need to keep servers running around the clock.A 5 MWh battery for the gridThe containerized system is designed for the point where a data center connects to its electricity supply. One of its intended uses is frequency regulation, which helps keep the grid stable by absorbing or releasing power as electricity supply and demand shift.EVE said the system can deliver 20,000 equivalent cycles in frequency-regulation applications and achieve 93.6% efficiency. It uses 315 amp-hour cells developed for that purpose. The company also said the system uses 20% less auxiliary power, which is the electricity needed to run the equipment that supports the battery itself.At the scale of a 100 MWh installation, EVE estimates the configuration could cut transportation costs by more than 40% and reduce land use by more than 13%. The company also displayed its Mr.Giant 3.0 system for longer-duration storage, reporting efficiency above 95.5% after 700 days of demonstrated operation.A 660 kW cabinet for short power spikesInside the data center’s power distribution network, EVE’s Fortron cabinet can supply 660 kW for five minutes, according to the company. It is designed for brief surges in power demand and can work with uninterruptible power supplies, which keep equipment running when its main supply is interrupted.EVE gave the cabinet a 15-year design life and said it can be integrated into power systems at the factory before shipment. The cabinet includes separate compartments to limit heat transfer, along with overcurrent protection and a fire suppression system.Backup power at the server rackEVE’s rack-level system combines a lithium iron phosphate battery with a capacitor backup unit. The capacitor can respond within a millisecond, the company said, while the battery can discharge rapidly to help smooth changes in power demand. EVE designed the combined system to handle fluctuations lasting from one millisecond to 10 seconds.The rack system’s switchover time of less than two milliseconds matters when the main supply drops and servers need backup immediately. During normal operation, the same equipment is designed to absorb brief changes in demand close to where they occur.EVE said offering equipment at all three levels could simplify purchasing and maintenance for data center operators. The lineup puts the grid battery, distribution cabinet, and rack backup under one supplier, from the point where electricity enters the facility to the racks where AI workloads run.