Packaged drinking water: What are gaps in testing, treatment and quality control?

Wait 5 sec.

The sanction of prosecution against Bisleri by the Food Safety and Standards Authority of India (FSSAI) raises questions about regulatory compliance, laboratory findings and how their significance is communicated. “These deserve careful distinction,” says Pawan Kumar Agarwal, its former CEO.He felt that while Bisleri must identify why the affected sample failed the requirements and strengthen its internal controls, FSSAI, too, has work to do. “Clarifying the scientific and analytical basis of its standards, examining differences between laboratory findings, and communicating the scope and health significance of such cases more clearly,” he told The Indian Express.Under Section 2.10.8 of the Food Safety and Standards Regulations, packaged drinking water can be sourced from surface water, civic water supply, groundwater, seawater or another consistent source. It can undergo processes such as decantation, filtration, activated carbon filtration, reverse osmosis, demineralisation, remineralisation and disinfection before being packed in sealed containers suitable for direct consumption.The standards prescribe microbiological, physical, chemical and toxic-substance parameters. These include the absence of coliform bacteria, Salmonella and Shigella, limits for turbidity and total dissolved solids, and specified limits for substances such as arsenic, lead, mercury and bromates.What changed in 2026?Following the removal of mandatory Bureau of Indian Standards (BIS) certification for packaged drinking water and mineral water in October 2024, FSSAI introduced a dedicated Scheme of Testing, effective January 1, 2026.The scheme requires manufacturers to maintain testing records and use FSSAI-notified NABL-accredited laboratories meeting ISO/IEC 17025 requirements. Microbiological parameters must be tested monthly, specified general chemical parameters once every three months, pesticide residues once every six months and all parameters prescribed under Regulation 2.10.8 once every six months.If microbiological non-compliance is detected, manufacturers must investigate the cause, take corrective action and restart production and dispatch only after satisfactory results for five consecutive batches. Records must be maintained for at least five years. The scheme also provides for increased testing frequency when parameters fail and risk-based inspections in cases of repeated non-compliance.Story continues below this adBromate findings and their significanceAccording to the company’s account, six samples were collected from its Goa facility in September 2025. Five met the applicable standards, while one recorded bromate at 12 micrograms per litre against the prescribed limit of 10. Following the company’s appeal in November 2025, referral testing found bromate below the limit of quantification and within the prescribed limit, as FSSAI subsequently clarified.Differences between laboratory results can reflect analytical uncertainty, sample handling or other factors. “Their cause needs examination; a difference cannot automatically be dismissed as being within the margin of error,” Agarwal said.Ozonation is a process used to disinfect water. It involves passing ozone, a highly reactive form of oxygen, through the water to kill harmful microorganisms. “However, if the source water contains bromide, a naturally occurring salt, ozone can react with it and form bromate as a by-product. Finding bromate in a sample does not necessarily mean that potassium bromate was deliberately added. Manufacturers need to check the source water for bromide, carefully control the ozonation process and test the finished water for bromate. The findings in this case do not justify a general conclusion that packaged drinking water is unsafe because of bromate,” Agarwal observed.PAH findings and their significanceThe referral laboratory reported PAHs at 0.144 micrograms per litre. FSSAI’s packaged drinking-water standard requires PAHs to be “not detectable”, making the finding a regulatory-compliance issue. The primary laboratory had reportedly recorded PAHs below 0.01 micrograms per litre. The difference between the reports warrants examination of the methods used and the individual compounds measured.Story continues below this adAccording to Agarwal, the level of PAHs found was about one-fifth of the WHO guideline for benzo[a]pyrene, one of the chemicals in this group. “This suggests that the level of benzo[a]pyrene was below the WHO guideline. However, to understand the significance of the overall finding, it is important to know which other PAHs were present and in what quantities. The WHO guideline applies to benzo[a]pyrene, not to the total amount of PAHs,” he said.A case for reviewing the requirement“Not detectable” does not mean absolute zero; it refers to the detection capability of the applicable analytical method.“If the substances, methods and detection limits are not clearly specified, increasingly sensitive instruments can change the compliance outcome without any change in the water itself. FSSAI should explain the scientific rationale for the requirement, clarify the PAHs covered and the analytical methods and detection limits used, and review whether explicit, health-based limits would provide more consistent protection. The existing requirement remains applicable until revised. Its breach should nevertheless be distinguished from an assessment of the actual health risk at the concentration found,” Agarwal said.According to the former FSSAI CEO, the immediate priorities are to establish the source of the reported PAHs, address the affected batch and verify corrective action. “Enforcement of existing requirements and scientific review of those requirements can proceed together,” Agarwal added.Story continues below this adWhere can the gaps occur?One important area is source-water quality. The new FSSAI scheme requires source water to be tested against prescribed parameters before use. Any change or addition of a source requires fresh testing, and the water can be used for regular production only after compliance is established.Manufacturers must also monitor purification and disinfection processes. Having filtration or reverse-osmosis equipment does not automatically guarantee that the output will consistently meet standards. The effectiveness of treatment depends on how the equipment is operated and maintained, whether filters and membranes are replaced when required and whether the treatment process is regularly monitored.Packaging is another aspect. The testing scheme includes checks on bottles, jars and closures, including migration tests. Reused containers of five litres and above must be durable and easy to clean or disinfect. Soiled, de-shaped or mutilated containers cannot be reused.However, periodic laboratory testing cannot replace day-to-day monitoring of production conditions. A satisfactory sample does not automatically establish that every batch meets the standards.Story continues below this adWhy does the issue extend beyond one company?The Bisleri-FSSAI controversy raises questions beyond one company or laboratory report. According to Dr Chandrakant Lahariya, a public health specialist, ensuring safe drinking water requires far more than occasional laboratory certification.“It demands protection of water sources, scientifically validated purification processes, routine monitoring for microbial and chemical contaminants, independent testing, and transparent regulatory oversight. Equally important are standardised sampling protocols, credible laboratories, public disclosure of findings and swift corrective action when standards are breached. Water safety cannot rest on corporate assurances or regulatory pronouncements alone; it must be demonstrated through verifiable evidence,” Dr Lahariya told The Indian Express.He also pointed out that a larger issue was being overlooked. “India’s expanding packaged drinking water market also reflects public anxiety about the safety of ordinary drinking water. Providing safe water is a fundamental government responsibility, not merely a commercial opportunity. Stronger regulation of packaged water is essential, but so is ensuring that public water supplies consistently meet drinking standards. Ultimately, success should be measured by whether every citizen can drink safe water without having to purchase reassurance in a plastic bottle,” he added.Dr Arun Gupta, paediatrician and convenor of Nutrition Advocacy in Public Interest (NAPi), said it was vital for the government to “do their job” and ensure the supply of safe drinking water. “Companies often resort to fear-based messaging that may create a perception about ordinary drinking water being unsafe while positioning packaged drinking water as a safer alternative. These marketing practices could mislead the consumer and promote unnecessary consumption of packaged water,” he said.Story continues below this adThe success of regulation must be measured by whether consumers can trust both packaged drinking water and their public water supplies.